Half of a guestroom control system is installed by the furniture factory. Headboard lighting, mirror-screen lighting, TV-panel lighting, the panel cut-outs and the charging outlets all sit in the joinery. The ceiling box, the riser and the bathroom circuit belong to the main contractor. This page sets out the split, the point heights and the sequence, so the two halves meet during fit-out rather than on the snag list.
Send a BOQ, drawing set or specification. You get a costed response, or the questions needed to produce one.
A control package is the room control unit, the panels and sensors, the wiring between them, and the scene logic that ties lighting, air conditioning, curtains and door status together. In an FF&E package it is specified alongside the casegoods, because most of the visible hardware is mounted in or on the furniture.
| Item | Typical figure |
|---|---|
| Control platform | Room control unit (RCU) with modular relay boards: integrated board, 12 / 17 / 21-way boards, separate fan-coil module |
| Network | TCP/IP to a floor switch; browser-based configuration, updated on site or remotely |
| Lighting domains per guestroom | Four: headboard, mirror screen, TV panel, bathroom |
| Domains installed by the FF&E factory | Three of the four |
| Scene presets | Welcome, sleep, night wake, morning, cinema, meeting, reading, work |
| Mounting heights | Doorbell and room status 1500 mm; bedside panel 1300 mm; TV and data 1600 mm; ceiling box 2700 mm; curtain track feed 2900 mm |
| Bedside charging | USB-C PD 65 W (two ports), USB-A 30 W, wireless charging pad recessed into the nightstand top |
| Sensor set | Door contact, card or presence detection, optional night-light sensor (some operators delete it in design review) |
| Issued with the package | Point schedule, wiring diagram, panel cut-out drawing, factory harness drawing, per-room test sheet |
The furniture factory does. Three of the four lighting domains in a standard guestroom are built into joinery, wired inside it, and tested before the piece is packed. The bathroom is the only domain that belongs entirely to the site trades. The drawing below is the split we work to.
Figure 1. A standard guestroom, four lighting domains, one bus. The FF&E factory owns the harness inside each furniture-mounted domain. The contractor owns the connector above the ceiling.
A control system specified after the casegoods are drawn is a control system installed after the casegoods are finished. These are the details that have to be on the shop drawing, not decided in the room:
These are the heights we coordinate to on Chinese hotel guestroom drawing sets. They are a starting point, not a rule: local code and the operator's brand standard override them, and the finished floor level has to be settled before anyone sets a box.
| Point | Height | Note |
|---|---|---|
| Ceiling service box (RCU and power) | 2700 mm | Above the ceiling with a hinged access panel; this is where the contractor's harness connector terminates |
| Curtain and sheer track feed | 2900 mm | One feed per track, left or right according to the track motor |
| TV and data | 1600 mm | Two data outlets, one for the TV and one for the media hub |
| Doorbell and room status panel | 1500 mm | Corridor face of the door frame; display readable at standing eye height |
| Bedside control panel and sockets | 1300 mm | Set to the same line as the switch plates so the elevation reads clean |
| Vanity mirror light | 1300 mm | Fed from the bathroom circuit, not from the furniture harness |
| Minibar fridge socket | 300 mm | Unswitched. Stays live with the card out |
| Ceiling access point | 95 mm cut-out | Wired back to the floor switch, not to the RCU |
The one distinction that causes most callbacks is switched versus unswitched power. The minibar runs on unswitched power and stays live with the card out. Everything a guest can turn off runs on switched power. Wire it the other way round and either the fridge goes warm overnight or the room never goes fully dark.
Scene programming is the part of the package a guest experiences directly and a value-engineering review cuts first. Five of the scenes do most of the work:
| Scene | What it switches |
|---|---|
| Pre-arrival cooling | Front desk marks the room occupied and the air conditioning starts, so the room is at setpoint before the guest opens the door |
| Welcome | Corridor light on as the door opens, curtains open, welcome message and background music on the room speakers |
| Sleep | TV off, curtains closed, lighting down to the night circuit, air conditioning to the sleep setpoint and fresh air running |
| Night wake | A floor-level or under-bed circuit at low output, so the guest can find the bathroom without turning on the room |
| Morning | Curtains open on schedule or on alarm, lighting ramps, music starts |
Two more rules sit behind those scenes. Card out steps the setpoint up and switches off after a timeout, and the room reports its status to the front desk, so housekeeping stops knocking on doors that are already empty. The scene list is usually written at commissioning rather than in the specification, which is why scene behaviour often differs between floors of the same hotel.
The controller is a modular board, not a fixed black box. Board size follows the number of switched circuits: a standard room usually lands on a 12-way board, a suite with a separate living-area zone on 17 or 21. Air conditioning runs through a dedicated fan-coil module rather than through lighting relays.
The control hardware is produced on a shorter cycle than the casegoods, so it rides the same container as the furniture rather than shipping as a separate consignment. That matters for more than freight: the panels and the joinery they mount into arrive together, and the factory harness has already been mated to a sample panel before either is packed.
Yes, and this is the detail most often missed. A switch plate is a visible surface in the same frame as the timber, the stone and the metal, at a distance a guest actually stands from it. Panel families run from large-plate touch glass to metal-framed and dot-touch plates, in the finishes the interior designer selects for the room. A champagne-gold plate set against a black-titanium door frame reads as a mistake at one metre.
Control packages go wrong at the seams between parties, not inside any one party's scope. This is the split we write into the point schedule at the start of a project.
| Party | Delivers |
|---|---|
| Owner / developer | Power and network to the floor, the specification, and a scene list agreed before commissioning |
| Interior designer | Panel positions and heights, plate and finish selection, cut-out coordination with the joinery drawings |
| Main contractor | Ceiling box at 2700 mm, riser and floor switch, bathroom lighting circuit, the harness connector, unswitched feed to the minibar |
| FF&E factory | Lighting and harness inside the headboard, mirror screen and TV panel; panel cut-outs in the joinery; wireless charging recess; USB modules; mounting for bedside and door plates; a per-room test before packing |
| Control vendor | Relay boards, panels, sensors, firmware, scene programming, commissioning, integration with the door lock and PMS |
| foshanFFE as integrator | The point schedule all five parties work from, the finish matching between plates and joinery, and the factory test that proves the furniture side before it ships |
Can smart control be added to a package already in production?
Not without rework. Panel cut-outs, the wiring void in the headboard and the recess in the nightstand top are machined before assembly. If the casegoods are already finished, the practical route is surface-mounted plates and an external driver box, which costs more per room and looks like what it is. The cheaper decision point is the shop drawing stage.
Does the FF&E factory install the control system?
It installs the part that lives inside the furniture: lighting, harness, panel mounting and the charging modules, tested room by room before packing. The controller, the floor network, the bathroom circuit and the commissioning are done on site by the control vendor and the main contractor. foshanFFE coordinates the two sides against one point schedule.
What happens if the contractor's connector does not match the furniture harness?
The furniture has to be opened on site. That is why the harness drawing is issued with the package and why the connector is specified, not assumed. Where a project cannot guarantee the contractor side, we ship a short adapter lead and a labelled terminal block with each room set.
Does a hotel need a full control system to specify this?
No. A room with ordinary switches still needs the wiring void, the cut-outs and the point heights, because the joinery has to be built for whatever goes in later. Specifying the physical provisions now and the electronics later is a normal sequence on phased refurbishments.
How does control affect the FF&E lead time?
The hardware is not the constraint; the drawing is. Panels, plate finishes and cut-out dimensions have to be frozen before the joinery is machined, and that approval sits in the same shop drawing cycle as the rest of the casegoods. Once approved, the control hardware rides the same production window and the same container as the furniture.
Which markets does this work in?
The electrical standard, plug type and voltage change by market, and the panels are made to the destination standard rather than adapted afterwards. Middle East and North American projects are quoted with the socket configuration and certification the local authority requires, confirmed at quotation rather than at delivery.
Control provisions are specified with the guestroom FF&E package, because they are built into the same casegoods. They are tested under the same inspection regime as the furniture, room by room, before packing. They ship in the same consolidated container program, so panels and joinery arrive together. The drawing conventions behind the point schedule are on the technical documentation page.
Panel locations, point heights and cut-outs are marked up against your own drawings, and returned with the FF&E quotation so the electrical and joinery packages are coordinated before either is priced.
Request a Coordinated Quotation